TSI AM520i SidePak Personal Aerosol Monitor

The SidePak Personal Aerosol Monitor AM520i is a small, single-channel, portable, battery-operated, data-logging, light-scattering laser photometer that provides real-time aerosol mass concentration readings of dusts, fumes, mists, smoke, and fog within a worker breathing zone. Newly designed inlet conditioners increase the mass concentration capability and provide size fraction cut points for PM10, PM4 (Respirable), PM5 (China Respirable), PM2.5 , PM1, and 0.8 μm Diesel Particulate Matter (DPM).

The SidePak AM520i has IECEx, ATEX, CSA and IECEx-SIM certifications, meaning it can help you protect workers and maintain compliance in a variety of potentially volatile environments.

Model

Sub Brand

Description

Sensitivity
Sensor Type 90° light scattering, 650 nm laser diode
Calibration Calibrated against a gravimetric reference using the respirable fraction of standard ISO 12103-1, A1 Test Dust
Aerosol Concentration Range 0.001 to 100 mg/m3
Particle Size Range 0.1 to 10 μm
Minimum Resolution 0.001 mg/m3
Zero Stability ±0.001 mg/m3 over 24 hours using 10 second time constant
Temperature Coefficient Approximately +0.0005 mg/m3 per °C (for variations from the temperature at which the instrument was last zeroed)
Flow Rate
Range User-adjustable, 0 to 1.8 liters/min (L/min) Note: Upper range is dependent on impactor or cyclone attached to the SidePak AM520 Monitor
Temperature Range
Operating Range 32° F to 120° F (0° C to 50° C)
Storage Range -4° F to 140° F (-20° C to 60° C)
Operational Humidity 0 to 95% RH, non-condensing
Time Constant (OLED Display)
Range User-adjustable, from 1 to 60 seconds
Built-in Inlets
Standard inlet Not size-specific
PM1.0 impactor 50% cut-off at 1.0 μm
PM2.5 impactor 50% cut-off at 2.5 μm
PM5.0 impactor 50% cut-off at 5.0 μm
PM10 impactor 50% cut-off at 10.0 μm
Attachable Cyclones
4 μm Dorr-Oliver 50% cut-off at 4.0 μm
0.8 μm DPM 50% cut-off at 0.8 μm
Alarms
Alarm Types General, STEL
Default Settings 0.5 mg/m3, 1 mg/m3, 3 mg/m3, 5 mg/m3, 15 mg/m3, Off
Programmable from 0.001 to 999 mg/m3 through TrakPro Software
Alarm Indicator 95 dBA (at one foot) audible horn, blinking red LED, flashing red OLED display
Ringback Delay 30 sec, 1 min, 3 min, 5 min, 10 min, Off
Data Logging
Data Points Approx. 80,000 (55 days logging once per minute)
Logging Interval User-adjustable, from 1 second to 60 minutes
User-Select Calibration Factors
Factory Setting 1.0 (non-adjustable)
Ambient Setting 0.38 (non-adjustable)
User-Defined Settings 5, with user-defined labels via TrakPro Software
Range 0.1 to 10.0, user-adjustable
Physical
External Dimensions 5.1 x 3.7 x 3.1 inch129.5 mm x 94 mm x 78.4 mm with 803300 battery
Weight 21 oz (0.62 kg) with 803300 battery
Display 159 x 128 resolution color OLED display
Tripod Mounting Nut ¼-20 female thread
Battery Pack (p/n 803311)
Rating 5400 mAH Li-Ion Pack
Run Time Greater than 20 hours at 1.7Lpm with a PM2.5 impactor
Charge Time 4.0 hours (typical with a fully depleted battery)
Power Supply (p/n 803302)
Input Voltage Range 100 to 240 VAC, 50 to 60 Hz
Output Voltage 12 VDC @ 3.0A
Maintenance
Factory Clean/Calibrate Recommended annually
User Zero Calibration Before each use
User Flow Calibration As needed with use of inlet conditioner
Communications Interface
Type USB 2.0
Connector, Instrument USB Micro-B (socket)
Minimum Computer Requirements for TrakPro Software
Communications Port Universal Serial Bus (USB) v2.0 or higher
Operating System Microsoft Windows 7, 8, or 10 (32-bit or 64-bit) operating systems
Approvals
AM520 with TSI Battery Pack P/N 803300
Immunity EN61326-1:2013
Emissions EN61326-1:2013 Class B
Safety IEC 61010-1:2010
IEC 60825-1:2014

Product Fact Sheet